MPD-810H-V - Boser MPD-810H-V 120W 30~120VDC DC-DC ATX Open Frame Power Supply...
Request Quote
For Price
- Part Number:
- MPD-810H-V
- Model Number:
- MPD-810H-V
- Make:
- BOSER
- Lead Time:
- Available
- Qty In Stock:
- Available
Boser MPD-810H-V 120W 30~120VDC DC-DC ATX Open Frame Power Supply Simple Type: Power Supply
Boser MPD-810H-V 120W open frame power supply.
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- None Available
Specifications
- Altitude: 0~10,000ft
- Connectors: DC Input Dinkle DT-35-B01W-03 or equivalent
- DC Output: Molex 5045-03A or equivalent
- DC Output: Molex 5273-14A or equivalent
- Dimensions: 8.38 x 15.24 x 3.81 cm; tolerance specified is +/-0.4mm
- Efficiency: The efficency is higher than 70% while measuring at nominal line and rated load
- EMI: FCC docket 20780 curve B / EN55022B
- EMS: IEC-801-2 Level 3 / IEC-801-3 Level 3 / IEC-801-4 Level 4
- Fan Output: Molex 5045-02A or equivalent
- Humidity: 10~90%; non-condensing
- Input Current: The maximum is 7A at 30VDC input
- Input Voltage: The range of input voltage is from 30~120VDC, nominal input voltage is 48 and 90VDC
- Inrush Current: The inrush current is less than 70A at 30VDC input
- Line Regulation: The line regulation is less than +/-2.5% at rated load with +/-10% change in input voltage
- Load Range: At the factory, the +5V output is set between 5.08V to 5.13V and all output at 60% rated load; the other outputs are checked to be within the accuracy range. The maximum total combined output power on the +3.3V and +5V rails is 70W. The max. load connot exceed 120W
- Load Regulation: The load regulation for +5V is less than +/-2%, for +12V is less than +/-5%, for -12V +/-5%, +3.3V is less than +/-5% while the measuring is done by changing the measured output loading +/-40% from 60% rated load, and keep other output is at 60% rated load
- Power Fail Signal: The power fail signal will go low at least 1ms before any of the output voltages fall below the regulation limits
- Power Good Output: Molex 5045-02A or equivalent
- Power Good Signal: The power is turned on, the power good signal will go high between 100ms to 500ms after all output DC voltage are within regulation limits
- Power On/Off: The power supply will start-up when the power On/Off pin be connected to secondary GND
- Protection: The power supply will generate the hiccup mode to protect itself against short circuit or over load condition, and will return to normal after wrong condition is removed
- Ripple And Noise: The peak to peak ripple and noise for +5V, +3.3V output are less than 100mV for +5Vsb is 120mV, for +12V is less than 120mV, for -12V is less than 200mV at ranted load and nominal input, which is measured by a 20MHz bandwidth limited oscilloscope and the each output is connected with a 0.47uF capacitor
- Safety: UL 60950 / CSA 22.2 No.234 / EN60950
- Temperature: 0~+50°C, outpur power is 120W forced air cooling, 85W convection cooling (operating); -20~+70°C (storage)
Applications
- None Available
Aliases